Setra 26412R5WD11T1C 0–2.5″ WC Unidirectional Low Differential Pressure Transducer

BRAND: Setra SKU: 26412R5WD11T1C

$219.71

MSRP: $252.67
You save 15%

0–2.5″ WC Unidirectional Low Differential Pressure Transducer

Free Shipping
Ships Today
Availability:

10 In Stock

Description

Setra 26412R5WD11T1C Low Differential Pressure Transducer Overview

The Setra 26412R5WD11T1C is a precision low differential pressure transducer engineered for reliable measurement of air and gas pressure in HVAC building automation and critical environment applications. With a unidirectional pressure range of 0 to 2.5 inches water column (WC), this transducer delivers accurate, stable readings where low-range differential pressure monitoring is essential — such as clean rooms, VAV systems, duct static pressure control, and filter monitoring.

Key Features
  • Pressure Range: 0 to 2.5″ WC (inches water column), unidirectional
  • Output Signal: 4 to 20 mA — industry-standard analog output for seamless integration with building automation systems and controllers
  • Accuracy: ±1% Full Scale (FS) — ensures dependable, repeatable measurements
  • Electrical Connection: Terminal strip for straightforward field wiring
  • Low differential pressure design — ideal for sensitive HVAC and critical environment monitoring
  • Setra quality construction for long-term durability and stability
Applications
  • VAV (Variable Air Volume) system pressure control
  • Duct static pressure monitoring
  • Clean room and laboratory pressure differential measurement
  • Air filter status and change monitoring
  • Building automation and energy management systems
  • HVAC air handling unit (AHU) control
Why Choose the Setra 26412R5WD11T1C

Setra is a trusted name in precision pressure sensing, and the Model 264 series is widely recognized for its accuracy and reliability in demanding HVAC and building automation environments. The 4–20 mA output signal is compatible with virtually all modern building automation systems and controllers, while the terminal strip connection simplifies installation. The ±1% FS accuracy rating ensures that your pressure readings are consistent and trustworthy, supporting optimal system performance and energy efficiency.

Additional information

Pressure

0" – 2.5" WC

Flow Direction

Unidirectional

Output Signal

4 – 20 mA

Accuracy

±1% FS

Connector Type

Terminal Strip

Measured Parameter

Differential Pressure

Application

Air Filter Monitoring, Building Automation, Clean Room / Laboratory, Duct Static Pressure Control, HVAC Air Handling Units, VAV Systems