Description

The Armstrong Furnace R37520B016 is an OEM L275F flame rollout switch designed to protect gas furnaces from dangerous flame rollout conditions. When burner flames escape the combustion chamber and roll out toward surrounding components, this safety switch detects the elevated temperature and interrupts the circuit, shutting down the furnace to prevent equipment damage and potential fire hazards.

Product Overview

This rollout switch is a direct OEM replacement part for compatible Armstrong Furnace systems. The “L275F” designation identifies the trip temperature threshold, providing reliable, repeatable protection every heating season. As a manual-reset device, it requires a technician to investigate and resolve the root cause of rollout before the furnace is returned to service — an important safety feature that prevents repeated unsafe operation.

Key Features
  • OEM Armstrong Furnace replacement rollout switch
  • L275F rated trip temperature for precise thermal protection
  • Manual-reset design ensures technician verification before restart
  • Protects against flame rollout and associated fire hazards
  • Interrupts furnace operation upon detecting unsafe temperatures
  • Direct drop-in replacement for compatible Armstrong Furnace models
Application
  • Designed for use in Armstrong Furnace gas heating systems
  • Mounts in the burner compartment area to monitor for rollout conditions
  • Compatible with Armstrong Furnace models specifying part number R37520B016
Why Rollout Switch Replacement Matters

A failed or tripped rollout switch that is bypassed — rather than properly replaced — creates a serious safety risk. Always replace a tripped rollout switch with a genuine OEM part like the R37520B016 and investigate the underlying cause of rollout, such as a cracked heat exchanger, blocked flue, or restricted combustion air, before restoring furnace operation.

Additional information

Trip Temperature

275°F (135°C)

Reset Type

Manual Reset

Switch Action

Opens On Temperature Rise

Safety Function

Flame Rollout Protection

Fuel Type

Gas

Application

Gas Furnace

Mount

Burner Compartment

OEM / Aftermarket

OEM

OEM Replacement

Yes