High Limit Temperature Control, Manual Reset, 210°F

Free Shipping
Ships Today
Availability:

2 In Stock

Description

The Burnham Boiler 108847-01 is an OEM-specified high limit temperature control engineered to safeguard hydronic boilers from dangerous overtemperature conditions. Calibrated to trip at 210°F, this critical safety device interrupts the burner circuit the moment supply water temperature exceeds the rated set point — and locks out until a technician manually resets the control. This design ensures the root cause of any temperature excursion is identified and resolved before the system returns to operation, protecting your heat exchanger, piping, and connected equipment from costly thermal damage.

Key Features
  • High limit temperature control with manual reset (M/R) operation
  • 210°F trip point delivers reliable, repeatable overtemperature protection
  • Manual reset lockout prevents automatic restart after a limit trip — a critical safety advantage
  • Direct OEM replacement part for compatible Burnham boiler models
  • Designed for hydronic heating and hot water boiler systems
  • Durable construction built to withstand demanding boiler room environments
Application

This high limit control mounts directly on the boiler and continuously monitors supply water temperature. When the 210°F set point is reached, the control immediately interrupts the burner circuit and locks out the system. Manual intervention is required to reset the device, ensuring a qualified technician inspects and corrects the underlying condition before resuming normal operation. It is the last line of defense against runaway temperatures in hydronic systems.

Product Specifications
  • SKU: 108847-01
  • Brand: Burnham Boiler
  • Control Type: High Limit Temperature Control
  • Reset Type: Manual Reset (M/R)
  • Temperature Set Point: 210°F
  • Application: Hydronic / Hot Water Boiler Systems

Additional information

Control Type

High Limit Temperature Control

Reset Type

Manual Reset

Temperature Set Point

210°F (99°C)

Application

Hydronic / Hot Water Boiler Systems

OEM Replacement

Yes

Safety Function

Burner Circuit Interruption On Overtemperature