Description
The First Alert CO7P01 is a plug-in carbon monoxide alarm designed for flexible installation — it can be plugged directly into a wall outlet or mounted using the included line cord. Powered by 120V AC with a 9V battery backup, the unit uses an electrochemical CO sensor paired with a solid-state piezo horn rated at 85 dB at 10 feet. A visual LED indicator confirms power status or alarm condition, and the alarm features two silence functions: low-battery silence (up to 8 hours) and alarm silence for temporarily quieting nuisance alarms. A full-function test button electronically simulates a CO condition to verify all alarm functions are working properly. The CO sensor is calibrated to avoid false alarms at low ambient CO levels while responding at established thresholds — alarming within 4–15 minutes at 400 PPM, 10–50 minutes at 150 PPM, and 60–240 minutes at 70 PPM. The unit resets automatically once CO levels clear. Designed for easy replacement, the CO7P01’s dimensions and screw positions match the CO605/CO606 legacy models. The alarm meets UL 2034, NFPA 72, and NFPA 101 requirements and is backed by a 7-year limited warranty. Installation must conform to NFPA 72 and local building codes; refer to the user’s manual for proper alarm placement guidance.
Features:
- Plug-in installation — mounts directly in outlet or via line cord
- Electrochemical CO sensor with 85 dB solid-state piezo horn
- 9V battery backup for continued protection during power outages
- Visual LED indicator for power and alarm status
- Low-battery silence (up to 8 hours) and nuisance alarm silence functions
- Full-function test button electronically simulates CO condition
- End-of-Life warning signal when alarm needs replacement
- Matches CO605/CO606 legacy model dimensions and screw positions for easy replacement
- Meets UL 2034, NFPA 72, and NFPA 101 requirements
- 7-year limited warranty
Specifications:
- Model: CO7P01
- Dimensions: 4.9″W x 3.4″H x 2.24″D
- Weight: 0.4 lb
- Operating Voltage: 120V AC with 9V battery backup
- Battery: 1 x 9V
- Operating Current: 0.09 A
- Temperature Range: 40°F to 100°F (4.4°C to 37.8°C)
- Humidity Range: 10–95% RH, non-condensing
- Audio Alarm: 85 dB minimum at 10 feet
- Sensor Type: Electrochemical
- Alarm Reset: Automatic when CO clears
- Compliance: UL 2034, NFPA 72, NFPA 101
- Warranty: 7-Year Limited
CO Sensor Alarm Response Times:
- 400 PPM: 4–15 minutes
- 150 PPM: 10–50 minutes
- 70 PPM: 60–240 minutes
- Will not alarm at constant levels below 30 PPM for 30 days







Reviews