ICM Controls ICM870 Soft Start Series, Built-In Start Capacitor – 32 Amps

BRAND: ICM Controls SKU: ICM870-32A

$217.50

MSRP: $250.13
You save 15%

Amperage: 32 Amps

Availability:

1027 In Stock

Description

WHICH MODEL DO I NEED?

Refer to your service panel or user manual to determine your actual RLA rating.

THIS MODEL: ICM870-32A: For use with a Compressor Load Amp Rating (RLA) of 16.1-32A Maximum

The ICM870 Soft Start is intended for residential, commercial, RV & marine applications. The ICM870 integrates compressor or motor in-rush current over startup time, thus reducing peak current demand on a power supply source by up to 70%.
Effectively reducing power draw to the A/C, the ICM870 utilizes a built-in self learning algorithm to deliver the optimal in-rush current per application. The ICM870 will monitor system health including voltage, current, compressor startup and integrity. Upon a fault condition, it will halt operation and initiate a 3 minute anti-short cycle routine while providing diagnostic fault information by means of an LED indicator.
* Note: ICM870-32A: For use with a Compressor Load Amp Rating (RLA) of 16.1-32A Maximum
Features:
  • Reduces in-rush current/draw necessary at startup by up to 70%
  • Prolong the life of the A/C by reducing excessive torque, wear and tear
  • 4-minute on start delay
  • Reduce loud noises, light flickering, and breaker trips
  • Built-in self-learning algorithm
  • Over-current protection
  • Over/under voltage monitoring
  • Built-in start capacitor
  • LED fault indicators
  • Ultrasonic sealed tamper-proof enclosure
  • Installation hardware is included

Still unsure of which model you need? Call our customer service team at: 1-844-727-8748 or click the Chat Now bubble in the bottom right.

Please DO NOT assume it is acceptable to upsize the ICM870-9A or ICM870-16A to the largest size (ICM870-32A) when you are unsure of the RLA current or when the current is close to the limit of the ICM870-16A. This practice will defeat the benefit of the Inrush reduction on smaller systems under 16 Amps and defeat the over current safety limit by allowing for a 20A trip point for over current on the ICM870-32A compared to an 11.25A trip point on the ICM870-16A. PLEASE choose the ICM870 based on RLA or by using the size vs tonnage chart shown.

Experiencing issues? Let us help! Your model may be flashing red lights but that doesn’t mean the item is defective. Call us at: 1-844-727-8748 before setting up a return.