Description
The ICM2813 is a direct replacement for the Lennox SureLight Series Boards and White Rodgers equivalent. The ICM2813 automated gas ignition control board monitors the ignition sequence including the inducer, pressure switch, hot surface igniter, gas valve, flame sense, and circulating blower while maintaining full safety circuit monitoring including the high limit switch, roll out switch and auxiliary limit switch circuits. Onboard diagnostics will indicate when a fault condition exists.
Features
- Controls the gas valve, inducer draft motor, circulating blower and hot surface ignitor
- Monitors system pressure and limit switches
- Microprocessor based precision
- Diagnostic LEDs aid in testing and trouble shooting