Description
Lennox 15M43 Rollout Switch Overview
The Lennox 15M43 is a manual reset, single-pole single-throw (SPST) rollout switch designed to protect furnaces and heating systems from hazardous flame rollout conditions. With a trip temperature of 270°F, this switch acts as a critical safety device — cutting power to the burner circuit the moment it detects abnormally high temperatures caused by flame rollout, blocked heat exchangers, or restricted airflow.
Key Features
- Trip Temperature: 270°F (132°C) for reliable high-heat detection
- Manual Reset: Requires technician intervention after tripping, ensuring the root cause is identified and corrected before resuming operation
- SPST (Single-Pole Single-Throw) configuration for straightforward circuit interruption
- Direct OEM replacement for compatible Lennox furnace models
- Compact design for easy installation in tight burner compartments
How It Works
The rollout switch is mounted near the burner assembly. Under normal operation, the switch remains closed, allowing the burner control circuit to function. If flame rollout occurs — typically due to a cracked heat exchanger, blocked flue, or restricted combustion air — temperatures at the switch location rise above 270°F, causing the bimetal element to open the circuit and shut down the burner. Because this is a manual reset device, the switch must be physically reset by a qualified technician after the underlying fault has been diagnosed and corrected.
Application
- Compatible with select Lennox gas furnaces requiring OEM rollout switch replacement
- Ideal for residential and light commercial heating applications
- Suitable for use during routine furnace maintenance, safety inspections, and component replacement
Why Manual Reset Matters
Unlike automatic reset switches, a manual reset rollout switch prevents the furnace from restarting until a technician has physically inspected and cleared the fault. This added layer of protection helps prevent repeated flame rollout events that could cause heat exchanger damage, carbon monoxide leaks, or fire hazards.
Specifications
- SKU: 15M43
- Brand: Lennox
- Trip Temperature: 270°F
- Reset Type: Manual Reset
- Switch Type: SPST (Single-Pole Single-Throw)
- Function: Rollout Switch / Flame Rollout Safety Limit







Reviews
There are no reviews yet.