Description
The Nordyne 1017676R is an OEM replacement pressure switch engineered for use in Nordyne heating systems. This dual-setting pressure switch monitors the negative pressure generated by the draft inducer to verify proper venting before allowing ignition to proceed — a critical safety function in modern gas furnaces.
How It Works
The pressure switch senses the suction created by the inducer blower. When adequate negative pressure is confirmed, the switch closes and signals the control board to continue the ignition sequence. If the required pressure is not achieved — due to a blocked flue, failed inducer motor, or venting issue — the switch remains open, locking out ignition and protecting the heat exchanger and home from hazardous conditions.
Key Specifications
- Part Number: 1017676R
- Make (Close) Setpoint: 0.90″ W.C.
- Break (Open) Setpoint: 0.60″ W.C.
- OEM Replacement for Nordyne furnace applications
- Designed for use with induced-draft and condensing furnace platforms
Features & Benefits
- Direct OEM replacement — no modifications required for compatible Nordyne units
- Dual pressure setpoints (0.90″ make / 0.60″ break) for precise draft monitoring
- Prevents ignition under unsafe venting conditions, protecting equipment and occupants
- Reliable switching action for long service life
- Easy field installation for qualified HVAC technicians
Application
The Nordyne 1017676R is intended for use in Nordyne-branded furnaces and may also apply to affiliated brands within the Nordyne family. Always verify compatibility with the specific model number of the unit being serviced before installation. Consult the equipment’s wiring diagram and service manual for proper installation procedures.







Reviews