Description
The Honeywell Resideo S8600M3001 Intermittent Pilot Control is a high-performance ignition module designed for residential and light commercial heating systems. It provides reliable ignition sequencing, flame monitoring, and safety shutoff for intermittent pilot central furnaces and heating appliances. This module is ideal for applications using natural gas or liquefied petroleum (LP) gas.
Specifications:
- Type of Fuel: Natural Gas, LPG
- Ignition Type: Intermittent Pilot
- Ignition Source: Internal high voltage spark generator
- Ignition Between Trail Time: 5 minute delay after failed trial for ignition
- Ignition Sequence: Continuous Retry
- Ignition Trial Time: 90 sec
- Ignition Trials To Lockout: continuous retry
- Pre-Purge: None
- Lockout Timing: Continuous Retry
- Flame Failure Response Time: 2 sec max
- Typical Ignition Hardware: Q345, Q3451
- Igniter-Sensor Rod: Single
- Typical Gas Control: VR8204, VR8304
- Product Depth: 2.63 in, 67mm
- Maximum Valve Load: 1 A Pilot, 1 A Main @ 24 V AC
- Frequency: 60 Hz
- Product Height: 3.94 in, 100 mm
- Product Width: 5.44 in, 138 mm
- Ambient Operating Temperature (Max): 175 °F, 79 °C
- Ambient Operating Temperature (Min): -40 °F, -40 °C