Description
The ICM318 is a microprocessor-based defrost control timer for residential and light-commercial heat pump systems. Designed as a direct, cost-effective replacement for Goodman B1226008 and ICM W1001-4 timers, it seamlessly integrates into existing units without rewiring—perfect for HVAC professionals and contractors who need easy installation and dependable performance.
Features:
- Replacement for Goodman B1226008 and PCBDM101(s)
- Low cost, time and temperature terminated defrost
- Test pins reduce test time by 256X
- High power output contact (1/2 HP @ 240 VAC)
- Strip heat, reversing valve outputs (24 VAC, 1 amp)
- Hold feature accumulates compressor run time
Specifications:
- Voltage: 24, 120, 240 VAC
- Frequency: 50/60 Hz
- Outdoor Fan Relay Output:1/2 HP @ 240 VAC
- Strip Heat, Reversing Valve Outputs: 24 Vac, 1 amp
- Defrost Time: Fixed 10 minutes
- Interval Time Between Defrosts: Pin-selectable 30/60/80 min